Commercial Burglary/CCTV and Access Control Platform
The new VISTA-128BP is an
eight partition, 128 zone UL commercial burglary control
panel that meets the demanding requirements of today’s
commercial installations while simplifying end-user
operation.
A revolutionary new
feature called Panel Linking allows multiple partitions,
panels—even buildings—to be armed, disarmed and have status
checked all from one location. Up to eight VISTA-128BP
panels can be linked together, and the control can be
integrated with ADEMCO’s PassPoint system (via the VISTA
Gateway Module) to provide a fully integrated security and
access control system. The VistaKey Access Control system
and the VistaView-100 CCTV Switcher can also be seamlessly
integrated with this powerful commercial platform.
|

Vista128BP Installation Guide PDF
Ademco
Vista 128BP User Guide PDF
Vista250BP Installation Guide PDF
Ademco
Vista 250BP User Guide PDF
Ademco Burglar Alarms By Honeywell
|
FEATURES
- Provides nine style-B hardwired zones
- Supports up to 119 additional zones using a built-in
polling (multiplex) loop interface
- Supports up to 128 wireless zones using 5881 type RF
receiver (fewer if using hardwired and/or polling loop
zones)
- Provides one power-limited bell circuit delivering
1.7Amp (max) at 12Vdc.
- Provides the ability to control eight separate
partitions independently, each functioning as if it had its
own separate control
- Accommodates 150 user codes with seven authority levels
- Accommodates 32 keypad macro commands per system
- Keeps a log of up to 512 events
- VistaView-100 CCTV support
- Supports up to 16 two-wire smoke detectors on zone 1
- Supports up to 50 latching-type glassbreak detectors on
zone 8
- Zone 7 may be used for keyswitch arming/disarming
- Integrates with PassPoint access control systems to
provide increased users, event log, and scheduling (up to 32
doors)
- Supports V-Plex addressable VistaKey access control (up
to eight doors and 250 cards)
- Easily programmed and maintained by the newly upgraded
Compass Windows-based downloader
- Supports up to 96 programmable relays
- Supports the ADEMCO 4286 VIP Module
- False alarm reduction features
New Enhancement:
- Two-Way RS232 (facility automation software support)
optional
- Supports eight numeric pager numbers
- Supports touch screen Advanced User Interface (AUI)
(Future)
- Smoke Detector Reset at keypad
- QUICK EXIT
- Group Bypass
- Arm Faulted
- Event Arming
- Scheduled check-in
- ARM STAY by group
Additional Features
Basic Hardwired Zones
Provides nine style-B hardwired zones with the following
characteristics:
- EOLR supervision (optional for zones 2-8) supporting N.O.
or N.C. sensors (EOLR supervision required for fire and UL
burglary installations)
- Individually assignable to one of eight partitions
- Up to 16 two-wire smoke detectors on zone 1
- Four-wire smoke or heat detectors on zones 1-8 (power to
four-wire smoke detectors must be supervised with an EOL
device)
- Up to 50 two-wire latching glassbreak detectors on zone
8
Polling Loop Expansion
Supports up to 119 additional zones using a built-in polling
(multiplex) loop interface. Current draw can total up to 128mA.
Polling loop zones have the following characteristics:
|
Scheduling
Provides the following scheduling capabilities:
- Open/close schedules (for control of arming/disarming and
reporting)
- Holiday schedules (allows different time windows for open/close
schedules)
- Timed events (for activation of relays, auto-bypassing and
unbypassing, auto-arming and disarming, etc.)
- Access schedules (for limiting system access to users by time)
- End user output programming mode (provides 20 timers for relay
control)
Eight Partitions
Provides the ability to control eight separate areas independently,
each functioning as if it had its own separate control. Partitioning
features include:
- A Common Lobby partition (1-8), which can be programmed to arm
automatically when the last partition that shares the common lobby
is armed and to disarm when the first partition that shares the
common lobby is disarmed
- A Master partition (9), used strictly to assign keypads for the
purpose of viewing the status of all eight partitions at the same
time (master keypads)
- All zones assignable to one of eight partitions
- Keypads assignable to one of eight partitions or to master
partition 9 to view system status
- Ability to assign relays to one or all eight partitions
- Ability to display fire and/or burglary and panic and/or trouble
conditions at all other partitions' keypads (selectable option)
- Certain system options selectable for each partition, such as
entry/exit delay and subscriber account number
New Enhancement
- allows multiple control panels to be networked together and
controlled from any keypad in the system:
- Control multiple zones, partitions, buildings from a central
location
- Check status, arm and disarm any partition from any keypad in
the system (based on user’s authority level)
- Users can have a different authority level in each partition and
access to different partitions in each panel
- Global Arming - users can arm and disarm all the partitions in
all the panels they have access to, with one set of keystrokes
Applications
The VISTA-128BP control is well suited for a variety of applications
as a burglary control and is supported by a diverse line of ADEMCO
initiating devices. Applications include medical and professional
buildings, supermarkets, churches or synagogues, office buildings,
schools, universities, strip malls, larger residences and factory or
warehouse environments.
Installation
The VISTA-128BP alarm system has been designed to mount both quickly and
easily. It meets all applicable requirements for UL-Commercial Burglary
installations, use the Vista-ULKT kit when an attack resistant enclosure
is required.
Agency Listings Burglary
- UL609 Grade A Local Mercantile Premises and Mercantile Safe and
Vault
- UL611/UL1610 Grades A, AA Central Station
- UL365 Grades A, AA Police Connect
- UL985 Household Fire
- California State Fire Marshall (CSFM)
- UL listing 1023 - Household Burglar Alarm
|