Napco MA3000LKD MA3000 Commercial Fire / Burglary Control
|
Complete Description Below:
Ordering And Information Above.
|
|
|
New Page 1
Napco
MA3000LKD MA3000 Commercial Fire / Burglary Control
Napco MA3000 Commercial Fire /
Burglary Mulitasking-Multiplexing-Partitioning Control
Battery, Box, & Keypads Sold Seperatly. Call To Order Box If Needed
Installation Manual
Program Manual
User Manual
|
• |
12 - 96 Fully Programmable
Zones (8 Zones on Board + 4 at each RP3000LCD Keypad) |
|
• |
8 Partitions • 8 Doors
Built-in Access Control |
|
• |
96 Simplified
Multi-function, multi-level User Codes |
|
• |
800 Event
History Log |
|
• |
8 to 64 Prog. Relays |
|
• |
Real Time Clock & 255
Event Scheduler |
|
• |
Expandable with EZM3008
8-Zone Multiplex Modules |
|
• |
On-Site Parallel
Printer Output |
|
• |
Advanced false
alarm prevention features for extra-simple user operation |
|
• |
Accessories: |
|
|
|
Housings - Standard
H1214, Commercial H1518 or Com’l Fire CF1518 EZM3008 8 Zone Multiplex Module |
|
RB3008 8-Relay Board ,
CF5530 Comm’l Fire Module |
|
RP3000LCDe
New! Dual Line Alpha Burglar/Fire/Access Keypad with 4 built-in zones |
|
CF3000LCDe
New! Dual Line Alpha Fire Marshall Keypad with 4 built-in zones |
|
PS3000 Heavy Duty
4A Power Supply |
|
MA3000 ADVANCED FEATURES:
• 12 to 96 Fully
Programmable Zones designed for UL Commercial and residential burglary and fire. • Includes 8 True Partitions
• 96
Multi-function User Codes
• 800-Event
History Log with Real Time Clock
• 255 Event
Scheduler
• 8 to 64
Programmable Auxiliary Relay Outputs Provision for the Incorporation of Home Automation
and Derived Channel/Long-Range Radio Phoneline Backup Systems
• Fuseless
Auto-Resettable Polyswitches
• Built-In Access
Control Capability - Up to 8 points of access control enabled at the Keypad. Access codes
can be logged by station, user ID and time.
• The access
control output is immediately available through the PMG wire at each Keypad.
• Exclusive
Sensor Watch Feature continuously monitors motion detectors for proper operation.
COMPLIANCES
• UL Burglary/UL
Fire; Commercial & Residential
(NFPA 72A/C, 71); NFPA 71 Signaling Systems for
Central Station, California State Fire Marshal (CSFM)
Commercial Fire, FM (pending); D.O.C., FCC.
CONTROL PANEL
• 8 E.O.L
Supervised, Programmable Zones for Burglary,
2- or 4- Wire Fir e/Commercial Fire or Panic
• Expandability
to 96 Zones with use of EZM multiplex
modules or keypad zones
• Programmable
Relay Outputs (1 for pulse) for: bell,
access control, fire reset, etc.
• Up to 96 Zones
programmable for fire and
"alarm verification by zone"
• 800 Event
History Log with Real Time Clock
• Log can be
sorted for printing or displayed at keypad
by 4 different categories.
• 0/C, system
troubles, alarm, fire
• Keypad Recall
of Events in History Log
• Up to 8
Programmable Areas/Partitions with
Keypad Management Mode
• 96
individually-reporting User Codes w/4 programmable
security levels each
• Secured Bypass
Option-disallows bypassing by other
than authorized users (based on security level)
• Two Separate
Interior Bypass Options per area
• Auto Arm/Auto
Disarm - Auto arming/disarming at a
predesignated time with holiday scheduling
• Manual Auto Arm
- Enables delayed arming of system
or area(s) by 1,2,3 or 4 hours
• 255 Event
Schedule, Programmable for 296 types
of events including: test timer, remote relay enable/
disable, auto arm/disarm service reminder message,
log down load, and download at pre-designated
increments of events
• On Board
Supervised Printer Output -Capability to print
log as events occur, or as selected, i.e., open/closes,
or in entirety per programmed schedule or with keypad
• Programmable
Log Download By Time and Volumes
(600 -750)
• Audible EZM
Zone Locator
• Programmable
E.O.L. Resistor by zone
• Diagnostics
Mode
• Dynamic Battery
Test (4 hr. intervals)
• Sensor Watch -
Checks for sensor activity over selectable
time duration
• Exit/Entry
Follower Zones
• Chime-by-Zone-Selectable
Duration
• Swinger
Shutdown by Zone
• Disable by Zone
Feature
• Separate
Dealer, User Program and Download Codes
• Flexible Watch
Modes by Area
• Fire
verification by zone
• Auto Bypass,
Interior Bypass, and Selectable Bypass
• 2 Separately
Programmable Entry Delay Times;
programmable Exit Delay Time
• 8 Stages of
Lightning/RFI Protection
• "True"
Dual Line Telco Cut Detection
• 24-hour
protection programmable for all zones
• Fail to
communicate indicated at command centers
FEATURES |
• Armed Output
• Low Battery
Output
• Resumes
Previous Status After Power Outages
• "Program
Change Alert" to CS
-supervises integrity
of original program
COMMUNICATOR
• Transmits in
all Major Formats, Including High Speed
Modem Formats: SIA MODEM 2, POINT ID, 4/3/1
• Pager/Beeper
Compatibility
• DPDT line
seizure
• 4 Telephone
numbers with subscriber ID numbers
assignable by area
• Open/Close
Suppression for Reduced Central
Station Traffic
• Fail-to-Close
Reporting and Fail-to-Open Reporting with
Auto Open (Disarm)/Close (Arm)
• Telco Line
Monitoring for Phone Line(s) with
Programmable Testing Time(s) (2nd Line Provided by
CF5530 Commercial Fire Module)
• Digital Dialer
Test to Central Station from Keypad
• Optional
Reporting of Bypassed Zones
• Reports Sensor
Watch "Troubles"
• Ability to Dial
Touch Tone digit labeled ("*"key) to
disable "Call Waiting" for the duration of the call
(not usable in all areas)
• Open report
after alarm
• Split, double
and back-up reporting
• Conditional
closing report with status
• Alarm and
restore codes: on fire, fire trouble,
low battery and AC loss
KEYPADS
• RP3000LCDe -
Backlit Dual-Line LCD Custom
Language Display (WHITE)
• CF3000LCDe Fire
Marshall Version (RED)
• Each Keypad
Incorporates Built-in EZM
for Four Additional, Fully-Programmable E.O.L.R.
Multiplexed Zones
• Auto
Scroll-Display of Open Zone(s)
• System Supports
up to 15 Keypads,
Providing a Total of up to 60 Additional Zones
• Fully-Supervised
with Tamper Feature
• Each Keypad
Includes 4 Independent,
Selectable Panics: Ambush, Fire, Auxiliary, Panic
• Built-in
Telephone List: Four Programmable
Emergency Phone Numbers
• Keypad Recall
of Events in History Log
• Total or
Selective History Log Print Commands
at Keypad
• Manual Auto Arm
- Provides Delayed Arming of System
or Area(s) by 1 through 4 hours
• Overview/Management
Mode Codes Enable Viewing
of Status of Entire System or Each Area, and Provides
Complete System Control Simply from a Keypad
• Complete
Alphanumeric Zone Directory
• Backlit,
Touch-Tone Full-Size Keys Brighten
When Touched |
SPECIFICATIONS
I nput
Power-16.5 VAC, Class 2 Plug in TRF11 40VA
Transformer or TRF14 50VA Transformer
Loop Resistance -300
ohms max.; 50 ohms for 2-wire
Relay Outputs -Burglary Output
-12Vdc,1.2A max., Fire
Output-SPDT wet contacts 12Vdc, 2A, Reset and Aux.
Relays-Resistive(cut for dry contacts)
Combined Standby Current -(Remote
EZMpower +
Auxiliary Output) (Household Burg/Fire and Commercial
Burg) With TRF14 50VA Transformer: 0.9A with RBAT-6
Battery: 1.15A with 2 RBAT-4 Batteries (Commercial Fire)
With TRF14 50VA Transformer: 0.5A with 3 RBAT-4
Batteries at max. bell output 1.2A (Requires PS3000 for
2.0A Bells)
MA3000LKDL 12V UL
Commercial/Residential
Burg/Fire/Access Control/Communicator with TRF14
Transformer supplied.
H1518 UL
Commercial/Merchantile Locking metal cabinet
with 16VAC/50VA Transformer supplied.
CB1518KIT Commercial
Burglary Kit (for H1518
Housing) w /attack-resistant shielding partitions plus
tamper switches
H1214 Standard UL
Household Listed metal panel
enclosure
RP3000LCDe Designer
Backlit Dual Line Alphanumeric
Display Command Center. Built-in 4 Zone EZM
Expansion Module, etc. (WHITE)
CF3000LCDe Fire-Dedicated
Model Dual Line Keypad with
signal shutdown and system restoral functions, etc. (RED)
EZM3008 8-Zone
Expansion Module
CF5530 Supervised
Dual Phone Line Switcher Module
for Commercial Fire
RM/RB3008 Relay
Board Provides 8 Programmable
Form "C" Relay Outputs
PS3000 Heavy-Duty
Power-Supply Module, l2Vdc,
4A for Commercial Use
MAV-15 Two-Way
Voice/Listen-In Module.
RPB-3 Surface
Mount Back Box w/ tamper for mounting
Command Centers on concrete or tile (WHITE)
RPB-3RED SurfaceMount
Back Box w/ tamper for
mounting keypads on concrete or tile(RED)
TRF14 Transformer, l6Vac/50VA,
Class 2
TRF15 Transformer, 18Vac/100VA,
Class 2,
in separate enclosure.
PCBL Parallel
Printer Cable
SYSTEM
COMPONENTS
• Up to 96
Multi-level User Codes Changeable by
Authorized Users
• AC Fail
Indication
• Diagnostic
Modes Include: Fault Find, Locate &
EZM Audible Zone-Locate |
|
|
|
|