Provides the highest level of security available.You can connect
the 7845C to almost any security system to transmit alarms and supervisory signals to the
Central Station in the event telephone service is interrupted.
After the radio is powered up - the LED should be observed to
determine the optimal installation location. The installation LED will indicate signal
strength - network contact and installation suitability. The radio is wired to the panel
per wiring diagram provided with the radio. It can be installed close to or inside the
panel itself. Installing 7845CZ within the panel may require the use of external
antenna 7825OC. The radio is mounted according to the mounting instructions
noting that the antenna must be vertical. Radio should not be mounted where it would be
obstructed by a steel structure or security doors and windows which may be pulled down at
night.
ELECTRICAL
Power
Powered from panel @ 150mA max.
Optional 12.5VDC @ 3AMP DC power pack
Battery Backup
Burg: 6V 0.5Ah rechargeable sealed lead acid battery
Current Requirements
90 mA normal operation; 400mA peak during transmission
MECHANICAL
Dimensions
4 Inch W x 6.5 Inch H x 1.5 InchD (without antenna)
Operating Temp
-30° to +60° C
Humidity
0% to 90% non-condensing
TRANSCEIVER
MicroBurst™ Compatible Cellular Radio
RF Power Output: 0.6 watts
Frequency Band
- 833-835 MHz Transmit
- 878-880 MHz Receive
Channel Separation: 30 kHz
Receiver Sensitivity: -115 dBm
Antenna: 5/8 wave helical unity gain
Serial Mode: Radio faults are reported to the panel on the serial
link
LED Indicators
3 status LED's visible when cover is on:
- Network connection status
- Power status
- Alarm delivery status
7 installation and set-up LED's visible when cover is off:
- Signal strength
- Installation suitability
- Operation mode
Zone Inputs and Alarm Functions:
Reporting format in zone mode: ADEMCO High Speed
Reporting format in serial Mode:
- ADEMCO contact ID on certain ADEMCO control
- Relay emulation mode in ADEMCO high Speed
- 4229 mode in ADEMCO high speed