New Page 2
Ademco Vista 128FB Commercial Fire/Burg/CCTV and Access Control
Platform
Kit Includes:
1-Vista 128FB-24 24 Volt Panel
1-6160CR
1-5140DLM
1-Transformer
Batteres Additional
Inatallation Manual
Program Manual
User
Manual
Designed to integrate seamlessly with CCTV, access control and ADEMCO's
full range of fire and burglary components, the VISTA-128FB provides the ultimate
protection of life and property. The UL listed Commercial Fire and Burglary Control
Platform controls up to eight partitions, and supports up to 128 zones/points using
hardwired, wireless and addressable V-Plex technologies. A diverse line of ADEMCO
initiating devices, notification circuits, digital dialers, keypads, RF receivers and
relays support this extremely powerful control platform.
The VISTA-128FB has been designed to mount quickly and easily in an
attack resistant cabinet, and is available in 12V and 24V models.
FEATURES
Supports addressable V-Plex access control points using VistaKey
(1 to 8 doors)
Supports up to 15 doors of access control using VISTA Gateway
Module (VGM)*
Supports CCTV applications with the new VistaView-100 CCTV
switcher module
Identifies the point or zone of a fire or alarm, using the new
FSA-8/FSA-24 Fire system annunciator
Stores up to 512 events and can accommodate 150 user codes
New E2 software simplifies programming
Easily programmed and maintained with newly upgraded Compass
Downloader software
Eight hardwired zones standard, expandable to 120 V-Plex
addressable points/zones or 128 wireless points/zones
Can control eight separate areas independently (8 partitions)
Two on-board notification (bell) circuits delivering 2.3A @ 12V
or 3.4 amp @ 24V
Automatic smoke detector sensitivity maintenance testing
Dual Battery Harness Included For Two Back Up Batteries
* Connects to Northern Computers Passpoint Access Control Systems.
Maximum 32 doors.
SPECIFICATIONS
Cabinet dimensions:
18"h x 14.5"w x 4.3"d
Environmental:
Storage temp:
-10°C to 70°C
Operating temp:
0°C to 50°C
Humidity:
85% RH
EMI:
Meets or exceeds the following requirements:
— FCC Part 15, Class B Device
— FCC Part 68
— IEC EMC Directive
AGENCY LISTINGS
Burglary:
— UL609 Grade A Local Mercantile Premises and Mercantile Safe
and Vault
— UL611/1610 Grades A, AA, Central Station
— UL365 Grades A, AA Police Connect
Fire:
— UL864/NFPA72 Local, Central Station and Remote Station
— Factory Mutual
— California State Fire Marshal
— MEA
— UL985
ADDITIONAL FEATURES
- Notification Appliance Circuit's (two)
— Programmable
— Temporal code compliant
— Individually silenceable
- Programmable on-board auxiliary relay
- SIA false alarm reduction features:
— Exit error logic
— Exit delay reset
— Cross zoning
— Call waiting defeat
— Recent close report
- Supports commercial hardwired, addressable V-Plex polling loop and wireless zones
- Hardwired zones
— Provides eight style B hardwired zones
— EOLR supervised for Fire and UL burglary installations
— Supports N.O or N.C. sensors
— Individually assignable to one or all eight partitions
— Up to 16 two-wire smoke detectors each zone 1 and 2 (total 32)
— Up to 50 two-wire glassbreak detectors on zone eight
- Patented addressable V-Plex polling loop technology
— Supports up to 120 two-wire multiplex zones/points
— Global polling technology for faster processing
— Increased current draw capacity (128mA)
— Supervised by panel
— Individually assignable to partitions, notification circuit (bell) output or aux
relay
— 4,000 ft capability without the use of shielded cable
— Extender/Isolation bus module
— Two-wire smoke detector zone/group expansion module adds two or four zones
— Eight zone - Class A and B extender module
— Eight zone - Class B extender module
— One zone supervised contact monitor module
- UL Listed wireless expansion
— Supports up to 128 wireless zones using 5881 receiver
— Supervised by control for check-in signals
— Tamper protection for transmitters
— Individually assignable up to eight partitions
— Supports UL268/NFPA listed wireless smoke detectors
- Access control integration
— Full integration with PassPoint Access Control System Complete Gateway access
functions
- Event reporting
- Local printer of access or VISTA related event
- Scheduled uploading of events to central station
- Stored events for one call retrieval
- Communication
— Phone mapping by zone response type
— Supports VIP Interactive Phone Voice Module
— Panel operation during download
— Uploading equipment list to central station
— Communication to PassPoint via VISTA Gateway Module (VGM)
APPLICATIONS
Supported by a diverse line of ADEMCO initiating devices, the
powerful VISTA-128FB is the ideal integrated fire and burglary control for applications
where a higher level of security is necessary including medical and professional
buildings, supermarkets, churches and synagogues, office buildings, schools, universities,
strip malls, larger residences and factory or warehouse environments.
Installation
The VISTA-128FB alarm system has been designed to mount both
quickly and easily in an attack resistant cabinet. It meets all applicable requirements
for UL commercial burglary installations.
Electrical:
Primary power:
— 80VAC @ 72 VA ADEMCO No. 1450
Quiescent current draw:
— 350mA
Backup battery:
— 12VDC, 12AH min to 34AAH max
— Lead acid battery (gel type)
Alarm power:
— 12VDC, 1.7A max for each notification (bell) circuit output
Aux. standby pwr:
— 12VDC, 1A max
Total power:
— 2.3A at 12VDC, 3.4A at 24VDC from all sources
Standby time:
— 24 hours with 1A standby load or 60 hours with 205mA max
standby load using 34AAH battery
Fusing:
— Battery input, aux. and notification (bell) circuit outputs
are protected using PTC circuit protectors. All outputs are power limited.
Main Dialer:
Line seize:
— Double Pole
Ringer equiv.:
— 0.7B
Formats:
— ADEMCO Low Speed, ADEMCO 4+2 Express, ADEMCO High Speed,
ADEMCO Contact ID, Sescoa and Radionics
DIAGRAM
COMPATIBLE DEVICES
See ADEMCO Group control accessories compatibility chart for complete
list
Auxiliary devices:
6160CR Alpha Keypad Commercial Fire
6139R - Red Alpha Keypad / Annunciator
FSA-8 & FSA-24 Fire System Annunciator
4204 - Relay Module, four form C contacts
4204CF - Two supervised output circuits
6220S - System printer used with 4100SM Serial Interface Module
5140DLM, FSA-8, FSA-24, FSAKSM Fire Annunciator
Two-wire and four-wire smoke detectors conventional:
Horn/Strobes:
Manual pull stations:
V-Plex (addressable) devices:
4101SN Single Relay/Zone Module
4190SN Remote Point Module - two zones
4190WH Two Point Multiplex RPM
4193SN Two Zone Serial Interface Module
4208U Loop Expansion Module - eight zones
4208SNF Class A/13 Expander Module
4209U Group Zoning Module - two/four zones
4293SN One Zone Serial Interface Module
4297 Isolation/Extender Module
V-Plex (addressable) smoke detectors:
Passive infrared detectors:
998MX
4275EX-SN
4278EX-SN
Quest 2260SN
V-Plex (addressable) contacts:
4939SN-WH
4944SN-WH
4959SN
Glassbreak detectors:
VISTA Interactive Phone Module
Optional 24V power supply
Long range radio:
Upgraded software:
Wireless devices:
5804 - Wireless Key
5804BD - Bi-Directional Key
5804BDV - Bi-Directional with voice
5816 - Door/Window Transmitter
5819 - Shock Sensor
5827BD - Bi-Directional Keypad
5849 - Glassbreak Detector
5881 Series - RF Receiver supporting 5800 wireless detectors
5890 - PIR
Access control:
VistaKey V-Plex (addressable) Access Control
VistaKey-SK Starter Kit
VistaKey-EX Expansion Kit
VGM Vista Gateway Module to PassPoint Access Control (Northern
Computers)
CCTV:
Commercial wireless devices:
5869 - Hold up Transmitter
5817CB - Wireless Commercial Transmitter
5881ENHC - Commercial Fire/Burg Receiver
5808LST - Wireless Smoke Detector
5809 - Wireless Heat Detector