Winland WB800 8 Channel Water Detector
|
Complete Description Below:
Ordering And Information Above.
|
|
|
Winland Waterbug - 8 zone, 12or 24 VAC/VDC (WB-800)
Includes:
1-WB-800 8 Zone Processor.
4 WB-1040 Surface Probes.
Spec
Sheet
PN# M-001-0005]
Eight zone water detection monitoring - Microprocessor controlled.
The model WB-800 operates on 12 or 24 Volt AC/DC and has a form C relay output that can be
connected to alarm panels, bells, dialers, etc. Unit also includes internal alarm buzzer
with silence switch and eight LEDs on console to identify the sensor in alarm. As many as
eight supervised sensor probes can be run up to 500 feet away (or 16 non-supervised
sensors). Each sensor probe has two contacts. When a film of water forms a bridge between
these contacts, the unit senses this and triggers the alarm output. The sensor will not
alarm due to condensation or high humidity. Four standard surface sensors are included
with the unit. |
Typical Applications:
- Residential or Vacation Homes
- Basement Sump Pumps
- Commercial Buildings
- Office and Computer Areas
- Unattended Buildings
- Greenhouses & Animal Buildings
- All Drain Areas
- Sprinkler Systems
|
Features:
- Reliable microprocessor design
- Versatile 12 or 24 Volt AC/DC power for operation
- No false alarms due to condensation or humidity
- Can monitor up to 8sensor probes - up to 500 feet away
- Provides (1) form "C" contact closure output for alarm
- Internal audible alarm with silence switch
- Easy surface mount installation
- One year parts and labor; subject to conditions of limited warranty.
|
Accessory Options:
- Standard surface sensor - P/N 1040
- Supervised surface sensor - P/N M-001-0006
- Under carpet sensor - P/N 1041
- Wall Transformer P/N 1111
Voltage: 110 VAC - 12VDC regulated, 300mA.
|
Specifications:
- Console Size: 6.55" x 4.70" x 1" (16.6 cm x 11.9 cm x 2.5 cm)
- Probe Size (standard P/N #1040): 2" x 3" x 0.88" (5.1 cm x 7.6 cm x 2.2
cm)
- Probe Size (under carpet P/N #1041): 2" x 3" x 0.18" (5.1 cm x 7.6 cm x
0.5 cm)
- Power Requirements: 12V or 24V AC or DC
- Current Draw (resting state): 75mA @ 12V or 24VDC, or 200mA @ 12V or 24VAC
- Current Draw (alarm condition): 125mA @ 12V or 24VDC, or 330mA @ 12V or 24VAC
- Sensitivity: Will not alarm due to high humidity or condensation
- Operating Temperature: Control and Probe 32? to +140? F (0? to +60? C)
- Outputs: Form C (SPDT) 1 Amp @ 24Vac, 1 Amp @ 30 VDC (not for direct high voltage
switching) Ç Audible alarm with silence feature
- Recommended Dist. Between Probes & Console: 500ft (152.4 m) maximum
- Recommended Max. Probes Per Console: 8 supervised or 16 non-supervised
|
|
|
|
|