DSC 832LCD Power 832 Power5 Kit
|
Complete Description Below:
Ordering And Information Above.
|
|
|
DSC 832LCD Power 832 Power5 Kit
Kit Includes:
1-Power 832
1-5501Z Fixed Display Keypad.
1-Bravo 3P Pet Motion.
1-Indoor Siren
1- Battery
1- Transformer
1-- RJ Jack & Cord.
Installation Manual Here
User Manual Here
Program Manual Here

Also
See DSC Wireless Equiptment & Accessories.
 |
 |
32 Zones Hardwired or Wireless. 2 Partitions, Hardwired
8 zones on main panel,
Add Up To 3 Addl, PC5108-433 - 8 zone expansion modules.
OR
You May Also Add Up To 32 Wireless Zones + 16 KeyChain Remotes Using The DSC PC5132-433
Wireless Reciever. |
Up to 12 Keypads
- up to 8 hardwired keypads and 4 wireless keypads
- 4 hardwired keypads available with zone input…
| - |
PC5508Z eight zone LED keypad |
| - |
PC5516Z sixteen zone LED keypad |
| - |
PC5532Z thirty two zone LED keypad |
| - |
LCD5500Z alphanumeric keypad |
- WLS910… wireless handheld keypad
- added wireless control is provided by …
| - |
WLS908… wireless panic pendant |
| - |
WLS909… wireless key |
32 Zones Hardwired or Wireless … 2
Partitions
Hardwired
- 8 zones on main panel
- PC5108 - 8 zone expansion module
- PC5108L - 8 zone expansion module plus Downlook video on Power832 PC5015
panel
- PC5100 - 32 zone addressable multiplexed loop interface module
- PC5700 …Canada only - 4 general purpose
zones, 2 waterflow zones, 1 ground fault zone, plus dual supervised telephone lines
- PC5720 …Canada only - 5 general purpose
zones, 2 waterflow zone, 1 ground fault zone, plus printer or DVACS communications
Wireless
- PC5132 - 32 zone wireless zone expansion module
14 PGM Outputs
- up to 5 high current outputs… 1 on main panel plus :
| PC5204 |
- |
4 output high current power supply module |
| - |
1 output fully supervised for siren output |
- up to 9 low current outputs… 1 on main panel plus :
| PC5208 |
- |
8 low current output module |
|
|
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
|
Advanced Communications
- supports all major formats including SIA and Contact ID
- LINKS1000™ cellular communication
- LINKS2150™ and LINKS2450™ long range radio communication
- DVACS communication using PC5400 or PC5720 modules
- Downlook video transmission using PC5108L module on Power832 PC5015 main control panel
- event initiated personal paging
- 3 phone numbers (3rd backs up primary number)
- 2 account numbers
Integrated Intercom Audio
- supports Central Station Two Way Voice and Home Intercom features using PC5928 audio
interface module, PC5921 intercom stations, and PC5904 two way listen-in stations
Integrated CCTV
- supports Downlook still frame video transmission using PC5108L module on Power832 PC5015
main control panel
- provides local VCR/monitor video switching for 8 cameras
Integrated Voice Assisted Security & Home
Automation
- Escort5580 & 5580TC provide voice assisted security and automation control for up to
32 X-10 devices plus thermostat control on 5580TC
Efficient Installation
- 4 wire communications bus (KEYBUS)
|
| - |
connect modules up to 1000' (305m) from
control panel |
|
| - |
PC5204 - 4 output high current power supply
module provides up to 1A auxiliary power |
|
| - |
main panel provides up to 550mA auxiliary
power |
|
|
|
| · P o w e r 8 3 2 S e c u r i t y S y s t e m · |
|

PC5010/5015 Main Control Panels |
|
- PC5010 main control panel - alarm only
- PC5015 main control panel - alarm plus Downlook video capability
- support up to 32 zones using any combination of up to :
| - |
8 hardwire zones on main panel |
| - |
8 hardwire zones using PC5108L video matrix
module (on PC5015 only) |
| - |
4 general purpose hardwire zones and 2
waterflow hardwire zones using PC5700 fire module (in Canada only) |
| - |
24 hardwire zones using PC5108 eight zone
expander modules |
| - |
8 keypad zones |
| - |
32 wireless zones using PC5132 wireless
receiver module |
- zone programming
| - |
all zones programmable as burglary or fire |
| - |
zone options include : Normally Closed loop,
Single End of Line (EOL) resistor, and Double EOL resistor *
* keypad zones cannot be programmed as fire zones
and cannot support Double EOL resistor supervision |
| - |
27 programmable zone types, 8 programmable
zone options |
- audible alarm output
| - |
supervised bell output - 700 mA @ 12VDC, PTC
protected, current limited at 3 A |
| - |
steady, pulsed, temporal pattern, or strobe
fire output |
| - |
additional supervised siren output is
available using PC5204 power supply module |
- programmable voltage outputs
| - |
1 high current 300mA PGM… can also be
used for 2 wire smoke with a maximum of 20 detectors at 15mA per detector |
| - |
1 low current 50mA PGM |
| - |
8 additional low current PGM outputs using
PC5208 module |
| - |
4 additional high current PGM outputs using
PC5204 module |
| - |
24 programmable options |
- local PCLINK™ and remote upload/download capability
| - |
program system using DLS software and direct
PC connection to control panel or via remote PC over telephone line |
| - |
view status and trouble conditions, and
system 128 event buffer |
| - |
remote access can be controlled by owner to
prevent unauthorized access to system |
- power supply
| - |
550mA @ 12.5VDC auxiliary power (400mA for UL
applications) |
| - |
positive temperature coefficient (PTC)
protected battery, AUX, and Bell output |
| - |
electronic protection of KEYBUS |
| - |
supervision of AC power loss, low battery,
auxiliary power failure |
| - |
internal clock locked to AC power frequency |
- EEPROM memory
| - |
will not lose programming or system status on
complete AC and battery failure |
- digital communicator
| - |
supports all major formats including SIA
& Contact ID |
| - |
supports LINKS1000™ cellular
communications |
| - |
supports LINKS2150™ and LINKS2450™
long range radio communications |
| - |
3 phone numbers (3rd backs up primary) |
| - |
2 account numbers |
| - |
DTMF or pulse dialing |
| - |
DPDT line seizure |
| - |
anti-jam feature |
| - |
split reporting of selected events to each
telephone number |
| - |
event initiated personal paging |
- battery required : 12V, 4 Ah, rechargeable sealed lead acid
- transformer required : 16.5VAC, 40VA
|
|
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
|
|

System Operation 2 system partitions… 2 account numbers
| - |
each partition acts as a separate alarm
system with any number of zones, user codes, keypads and individually programmable
features |
- 38 - 4 or 6 digit access codes
| - |
32 user codes, 1 system master code, 2
partition master codes, 2 duress codes, and 1 maintenance code |
- automatic arming by partition
| - |
each partition may be programmed to auto-arm
at its own time each day |
- keypad lockout
| - |
panel can be programmed to lockout keypad if
a series of incorrect access code entries are made |
- 'quick arm' and 'quick exit'
| - |
allows users to arm and exit easily |
- 'stay/away' zones and 'stay' arming
| - |
security of perimeter arming while premise is
occupied |
- door chime
| - |
programmable by zone |
| - |
monitor a door by having keypad beep when the
door is opened and again when door is closed |
- 128 event buffer
| - |
all events automatically stored with time and
date stamp to buffer |
| - |
events can be printed on-site using the
PC5400 serial printer interface module, viewed through an LCD Keypad, or viewed and
printed via PC using DLS software |

Full Supervision
The system continuously monitors the following trouble conditions :
- AC power failure
- trouble by zone
- fire trouble
- telephone line trouble
- low battery
- bell output trouble
- loss of internal clock
- tamper by zone
- fail to communicate
- aux power supply fault
- module fault (supervisory or tamper)
- camera troubles (on PC5015 with Downlook)

False Alarm Prevention Features
- audible exit delay
- audible exit fault
- quick exit
- urgency on entry delay
- swinger shutdown
- cross zone alarm
- recent closing transmission
- burglary verified timer *
- double hit timer *
- communication delay
- rotating keypress buffer
- arm/disarm bell squawk
* on PC5015 v2.2x and higher
|
|
|
|
|
|