Napco MA3000LKD MA3000 Commercial Fire / Burglary Control

GE-Caddx-ITI Security Systems

   | Home  |  Bookmark Page | Give A Gift | For Beginners | Support Videos | SSL Contact Us |

Burglar Alarm Monitoring

 



 
   Home Alarm Systems

 

 

Click Here For A Complete Line Of Our Security Produsts

Napco MA3000LKD MA3000 Commercial Fire / Burglary Control

Home Alarm Systems Alarm Monitoring
Manufacture: Napco
Part Number:: MA3000LKD

Napco MA3000LKD MA3000 Commercial Fire / Burglary Control
Kit Includes:
1-MA3000LKD 12-96 Zone Control Replacement Only
1-Transformer.
Box Not Included.
Call To Order Which Box You Need If Any.

List Price: US$326.38
Your Price: US$261.10

 

Prices Subject To Change Without Notice

Burglar Alarm Systems Home Security Systems

Complete Description Below: Ordering And Information Above.


 

New Page 1

Napco MA3000LKD MA3000 Commercial Fire / Burglary Control

Napco MA3000 Commercial Fire /Burglary Mulitasking-Multiplexing-Partitioning Control

Battery, Box, & Keypads Sold Seperatly. Call To Order Box If Needed

Installation Manual
Program Manual
User Manual

12 - 96 Fully Programmable Zones (8 Zones on Board + 4 at each RP3000LCD Keypad)
8 Partitions • 8 Doors Built-in Access Control
96 Simplified Multi-function, multi-level User Codes
800 Event History Log
8 to 64 Prog. Relays
Real Time Clock & 255 Event Scheduler
Expandable with EZM3008 8-Zone Multiplex Modules
On-Site Parallel Printer Output
Advanced false alarm prevention features for extra-simple user operation
Accessories:
Housings - Standard H1214, Commercial H1518 or Com’l Fire CF1518 EZM3008 8 Zone Multiplex Module
RB3008 8-Relay Board , CF5530 Comm’l Fire Module
RP3000LCDe New! Dual Line Alpha Burglar/Fire/Access Keypad with 4 built-in zones
CF3000LCDe New! Dual Line Alpha Fire Marshall Keypad with 4 built-in zones
PS3000 Heavy Duty 4A Power Supply

MA3000 ADVANCED FEATURES:

12 to 96 FullyProgrammable Zones designed for UL Commercial and residential burglary and fire. Includes 8 True Partitions

96Multi-function User Codes

800-EventHistory Log with Real Time Clock

255 EventScheduler

8 to 64Programmable Auxiliary Relay Outputs Provision for the Incorporation of Home Automationand Derived Channel/Long-Range Radio Phoneline Backup Systems

FuselessAuto-Resettable Polyswitches

Built-In AccessControl Capability - Up to 8 points of access control enabled at the Keypad. Access codescan be logged by station, user ID and time.

The accesscontrol output is immediately available through the PMG wire at each Keypad.

ExclusiveSensor Watch Feature continuously monitors motion detectors for proper operation.

COMPLIANCES

UL Burglary/ULFire; Commercial & Residential
(NFPA 72A/C, 71); NFPA 71 Signaling Systems for
Central Station, California State Fire Marshal (CSFM)
Commercial Fire, FM (pending); D.O.C., FCC.

CONTROL PANEL

8 E.O.L Supervised, Programmable Zones for Burglary,

2- or 4- Wire Fir e/Commercial Fire or Panic

Expandability to 96 Zones with use of EZM multiplex

modules or keypad zones

Programmable Relay Outputs (1 for pulse) for: bell,

access control, fire reset, etc.

Up to 96 Zones programmable for fire and

alarm verification by zone

800 Event History Log with Real Time Clock

Log can be sorted for printing or displayed at keypad

by 4 different categories.

0/C, system troubles, alarm, fire

Keypad Recall of Events in History Log

Up to 8 Programmable Areas/Partitions with

Keypad Management Mode

96 individually-reporting User Codes w/4 programmable

security levels each

Secured Bypass Option-disallows bypassing by other

than authorized users (based on security level)

Two Separate Interior Bypass Options per area

Auto Arm/Auto Disarm - Auto arming/disarming at a

predesignated time with holiday scheduling

Manual Auto Arm - Enables delayed arming of system

or area(s) by 1,2,3 or 4 hours

255 Event Schedule, Programmable for 296 types

of events including: test timer, remote relay enable/

disable, auto arm/disarm service reminder message,

log down load, and download at pre-designated

increments of events

On Board Supervised Printer Output -Capability to print

log as events occur, or as selected, i.e., open/closes,

or in entirety per programmed schedule or with keypad

Programmable Log Download By Time and Volumes

(600 -750)

Audible EZM Zone Locator

Programmable E.O.L. Resistor by zone

Diagnostics Mode

Dynamic Battery Test (4 hr. intervals)

Sensor Watch - Checks for sensor activity over selectable

time duration

Exit/Entry Follower Zones

Chime-by-Zone-Selectable Duration

Swinger Shutdown by Zone

Disable by Zone Feature

Separate Dealer, User Program and Download Codes

Flexible Watch Modes by Area

Fire verification by zone

Auto Bypass, Interior Bypass, and Selectable Bypass

2 Separately Programmable Entry Delay Times;

programmable Exit Delay Time

8 Stages of Lightning/RFI Protection

True Dual Line Telco Cut Detection

24-hour protection programmable for all zones

Fail to communicate indicated at command centers

FEATURES

Armed Output

Low Battery Output

Resumes Previous Status After Power Outages

Program Change Alert to CS -supervises integrity

of original program

COMMUNICATOR

Transmits in all Major Formats, Including High Speed

Modem Formats: SIA MODEM 2, POINT ID, 4/3/1

Pager/Beeper Compatibility

DPDT line seizure

4 Telephone numbers with subscriber ID numbers

assignable by area

Open/Close Suppression for Reduced Central

Station Traffic

Fail-to-Close Reporting and Fail-to-Open Reporting with

Auto Open (Disarm)/Close (Arm)

Telco Line Monitoring for Phone Line(s) with

Programmable Testing Time(s) (2nd Line Provided by

CF5530 Commercial Fire Module)

Digital Dialer Test to Central Station from Keypad

Optional Reporting of Bypassed Zones

Reports Sensor Watch Troubles

Ability to Dial Touch Tone digit labeled (*key) to

disable Call Waiting for the duration of the call

(not usable in all areas)

Open report after alarm

Split, double and back-up reporting

Conditional closing report with status

Alarm and restore codes: on fire, fire trouble,

low battery and AC loss

KEYPADS

RP3000LCDe - Backlit Dual-Line LCD Custom

Language Display (WHITE)

CF3000LCDe Fire Marshall Version (RED)

Each Keypad Incorporates Built-in EZM

for Four Additional, Fully-Programmable E.O.L.R.

Multiplexed Zones

Auto Scroll-Display of Open Zone(s)

System Supports up to 15 Keypads,

Providing a Total of up to 60 Additional Zones

Fully-Supervised with Tamper Feature

Each Keypad Includes 4 Independent,

Selectable Panics: Ambush, Fire, Auxiliary, Panic

Built-in Telephone List: Four Programmable

Emergency Phone Numbers

Keypad Recall of Events in History Log

Total or Selective History Log Print Commands

at Keypad

Manual Auto Arm - Provides Delayed Arming of System

or Area(s) by 1 through 4 hours

Overview/Management Mode Codes Enable Viewing

of Status of Entire System or Each Area, and Provides

Complete System Control Simply from a Keypad

Complete Alphanumeric Zone Directory

Backlit, Touch-Tone Full-Size Keys Brighten

When Touched

SPECIFICATIONS

Input Power-16.5 VAC, Class 2 Plug in TRF11 40VA

Transformer or TRF14 50VA Transformer

Loop Resistance-300 ohms max.; 50 ohms for 2-wire

Relay Outputs-Burglary Output -12Vdc,1.2A max., Fire

Output-SPDT wet contacts 12Vdc, 2A, Reset and Aux.

Relays-Resistive(cut for dry contacts)

Combined Standby Current-(Remote EZMpower +

Auxiliary Output) (Household Burg/Fire and Commercial

Burg) With TRF14 50VA Transformer: 0.9A with RBAT-6

Battery: 1.15A with 2 RBAT-4 Batteries (Commercial Fire)

With TRF14 50VA Transformer: 0.5A with 3 RBAT-4

Batteries at max. bell output 1.2A (Requires PS3000 for

2.0A Bells)

MA3000LKDL 12V UL Commercial/Residential

Burg/Fire/Access Control/Communicator with TRF14

Transformer supplied.

H1518 UL Commercial/Merchantile Locking metal cabinet

with 16VAC/50VA Transformer supplied.

CB1518KIT Commercial Burglary Kit (for H1518

Housing) w /attack-resistant shielding partitions plus

tamper switches

H1214 Standard UL Household Listed metal panel

enclosure

RP3000LCDe Designer Backlit Dual Line Alphanumeric

Display Command Center. Built-in 4 Zone EZM

Expansion Module, etc. (WHITE)

CF3000LCDe Fire-Dedicated Model Dual Line Keypad with

signal shutdown and system restoral functions, etc. (RED)

EZM3008 8-Zone Expansion Module

CF5530 Supervised Dual Phone Line Switcher Module

for Commercial Fire

RM/RB3008 Relay Board Provides 8 Programmable

Form C Relay Outputs

PS3000 Heavy-Duty Power-Supply Module, l2Vdc,

4A for Commercial Use

MAV-15 Two-Way Voice/Listen-In Module.

RPB-3 Surface Mount Back Box w/ tamper for mounting

Command Centers on concrete or tile (WHITE)

RPB-3RED SurfaceMount Back Box w/ tamper for

mounting keypads on concrete or tile(RED)

TRF14 Transformer, l6Vac/50VA, Class 2

TRF15 Transformer, 18Vac/100VA, Class 2,

in separate enclosure.

PCBL Parallel Printer Cable

SYSTEM

COMPONENTS

Up to 96 Multi-level User Codes Changeable by

Authorized Users

AC Fail Indication

Diagnostic Modes Include: Fault Find, Locate &

EZM Audible Zone-Locate

Internet Security By ControlScan

 

Ademco-Honeywell

GE-ITI

Caddx
Napco
Visonic
More Products

 

Alarm Monitoring - Central Station Services

HAVE ANY QUESTIONS? OR YOU NEED 24 HOUR SALES/SUPPORT?
You May
Contact Us At Our 24 HOUR HOT LINE.

Privacy Policy

More Products

| Ademco | DSC | ITI | Napco | Alarm Systems | X-10 | Aiphone | Caddx |

ITI Layout Section

 
Alpine Alarms Inc-Nassau Security - Alarm Shoppe