GE 2 Amp Supervised Power Supply For The Concord 4

Home Alarm Systems Alarm Monitoring
Manufacture: GE-ITI
Part Number:: 600-1019

GE 2 Amp Supervised Power Supply For The Concord 4
Ties Into Keypad Bus For Supervision
24VAC 50VA Transformer Included
Required 12v8AH Battery Not Included

List Price: US$195.85
Your Price: US$147.83

 

Prices Subject To Change Without Notice

Burglar Alarm Systems Home Security Systems

Complete Description Below: Ordering And Information Above.


 

GE 2 Amp Supervised Power Supply For The Concord 4

Installation Instructions

Description

The power supply provides an additional 12 VDC, 2 amps (current limited) for Concord 4 system devices and is supervised via the SuperBus® 2000 digital data bus.

Note: For 24 hour backup, external power drain is limited to 95mA (during normal standby conditions) using a 4.5 Ah battery, or 190mA continuous using a 7.0 Ah battery.

The power supply uses a 24 VAC, 50 VA power transformer. In case of an AC power failure, a 12 VDC, 4.5 or 7 Ah backup battery (not included) provides power to connected devices. The battery is tested by the power supply on power up, every two minutes afterward, and whenever the panel tests its own backup battery.

The power supply also includes a hardwire zone input that accepts normally open (NO) or normally closed (NC) intrusion detection devices. The power supply can be located inside the Concord 4/Concord Express V4 cabinet or it can be mounted in a separate Concord Residential Enclosure (444-1700 and 444-1711 ordered as a separate kit) or Concord Commercial Expansion Enclosure (444-1391 ordered as 60-816). See Mounting inside panel cabinet on page 2, Mounting inside Concord residential enclosure on page 2, and Mounting inside Concord Commercial enclosure on page 3 for more information on mounting in a separate enclosure.

Figure 1 describes the power supply main components. by the wire runs needed to provide power to devices with minimal loss on the +12V OUT wire. Table 1 shows the maximum wire runs between the power supply +12V OUT  terminal and the devices it will power.

For UL installations, the +12V OUT is not fully supervised for open circuits. Therefore, sirens cannot be connected directly to the output. • For large installations with long wire runs, power supply location is important. The total system wiring length (all partitions) for all bus devices connected to a Concord 4/ Concord Express V4 panel must not exceed 4,000 feet. This not only includes the power supply bus and power connections to the panel, but also any bus devices you may connect to the power supply. For example, touchpads and other bus devices in a remote partition should be connected to the power supply rather than running the wires all the way to the panel (Figure 2). Table 1. Maximum +12V OUT wire length Wire Gauge Maximum wire length from power supply +12V OUT terminal 22 100 feet 18 200 feet 16 350 feet 14 550 feet

Internet Security By ControlScan

 

Ademco-Honeywell

GE-ITI

Caddx
Napco
Visonic
More Products

 

Alarm Monitoring - Central Station Services

HAVE ANY QUESTIONS? OR YOU NEED 24 HOUR SALES/SUPPORT?
You May
Contact Us At Our 24 HOUR HOT LINE.

Privacy Policy

More Products

| Ademco | DSC | ITI | Napco | Alarm Systems | X-10 | Aiphone | Caddx |

ITI Layout Section

 
Alpine Alarms Inc-Nassau Security - Alarm Shoppe