New Page 1GRI TSC20 Series Pin Plunger and Tamper Switch
Installation Instructions
As Plunger Switch
Mount the switch (surface or recessed) so the door or window will actuatethe plunger fully when it is closed. Run the leads into the hole or dress them along theside of the mounting box after soldering. Tes for continuity.
Adjust the self tapping screw on the plunger to get proper plunger action.
As Tamper Switch
Locate switch so removal of the covering plate or door will allow theplunger to be fully extended. Splice wires to tamper circuit and test.
Plunger Travel.............0.25