DSC 832LCD 8-32 Control With LCD Alpha Keypad
|
Complete Description Below:
Ordering And Information Above.
|
|
|
Kit Includes: 1-Power 832 Panel. 1-LCD5500Z Alpha English Keypad. 1-12V 7AH Battery 1-16.5V 40Va Transformer All Manuals Included Installation Manual Here User Manual Here Program Manual Here
 AlsoSee DSC Wireless Equiptment & Accessories. User Manual Here
 |  | 32 Zones Hardwired or Wireless. 2 Partitions, Hardwired 8 zones on main panel, Add Up To 3 Addl, PC5108-433 - 8 zone expansion modules. OR You May Also Add Up To 32 Wireless Zones + 16 KeyChain Remotes Using The DSC PC5132-433 Wireless Reciever. | Up to 12 Keypads - up to 8 hardwired keypads and 4 wireless keypads
- 4 hardwired keypads available with zone input…
| - | PC5508Z eight zone LED keypad | | - | PC5516Z sixteen zone LED keypad | | - | PC5532Z thirty two zone LED keypad | | - | LCD5500Z alphanumeric keypad | - WLS910… wireless handheld keypad
- added wireless control is provided by …
| - | WLS908… wireless panic pendant | | - | WLS909… wireless key | 32 Zones Hardwired or Wireless … 2 Partitions Hardwired - 8 zones on main panel
- PC5108 - 8 zone expansion module
- PC5108L - 8 zone expansion module plus Downlook video on Power832 PC5015 panel
- PC5100 - 32 zone addressable multiplexed loop interface module
- PC5700 …Canada only - 4 general purpose zones, 2 waterflow zones, 1 ground fault zone, plus dual supervised telephone lines
- PC5720 …Canada only - 5 general purpose zones, 2 waterflow zone, 1 ground fault zone, plus printer or DVACS communications
Wireless - PC5132 - 32 zone wireless zone expansion module
14 PGM Outputs - up to 5 high current outputs… 1 on main panel plus :
| PC5204 | - | 4 output high current power supply module | | - | 1 output fully supervised for siren output | - up to 9 low current outputs… 1 on main panel plus :
| PC5208 | - | 8 low current output module | | | . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | Advanced Communications - supports all major formats including SIA and Contact ID
- LINKS1000™ cellular communication
- LINKS2150™ and LINKS2450™ long range radio communication
- DVACS communication using PC5400 or PC5720 modules
- Downlook video transmission using PC5108L module on Power832 PC5015 main control panel
- event initiated personal paging
- 3 phone numbers (3rd backs up primary number)
- 2 account numbers
Integrated Intercom Audio - supports Central Station Two Way Voice and Home Intercom features using PC5928 audio interface module, PC5921 intercom stations, and PC5904 two way listen-in stations
Integrated CCTV - supports Downlook still frame video transmission using PC5108L module on Power832 PC5015 main control panel
- provides local VCR/monitor video switching for 8 cameras
Integrated Voice Assisted Security & Home Automation - Escort5580 & 5580TC provide voice assisted security and automation control for up to 32 X-10 devices plus thermostat control on 5580TC
Efficient Installation - 4 wire communications bus (KEYBUS)
| | - | connect modules up to 1000' (305m) from control panel | | | - | PC5204 - 4 output high current power supply module provides up to 1A auxiliary power | | | - | main panel provides up to 550mA auxiliary power | | | | | · P o w e r 8 3 2 S e c u r i t y S y s t e m · | |  PC5010/5015 Main Control Panels | | - PC5010 main control panel - alarm only
- PC5015 main control panel - alarm plus Downlook video capability
- support up to 32 zones using any combination of up to :
| - | 8 hardwire zones on main panel | | - | 8 hardwire zones using PC5108L video matrix module (on PC5015 only) | | - | 4 general purpose hardwire zones and 2 waterflow hardwire zones using PC5700 fire module (in Canada only) | | - | 24 hardwire zones using PC5108 eight zone expander modules | | - | 8 keypad zones | | - | 32 wireless zones using PC5132 wireless receiver module | - zone programming
| - | all zones programmable as burglary or fire | | - | zone options include : Normally Closed loop, Single End of Line (EOL) resistor, and Double EOL resistor * * keypad zones cannot be programmed as fire zones and cannot support Double EOL resistor supervision | | - | 27 programmable zone types, 8 programmable zone options | - audible alarm output
| - | supervised bell output - 700 mA @ 12VDC, PTC protected, current limited at 3 A | | - | steady, pulsed, temporal pattern, or strobe fire output | | - | additional supervised siren output is available using PC5204 power supply module | - programmable voltage outputs
| - | 1 high current 300mA PGM… can also be used for 2 wire smoke with a maximum of 20 detectors at 15mA per detector | | - | 1 low current 50mA PGM | | - | 8 additional low current PGM outputs using PC5208 module | | - | 4 additional high current PGM outputs using PC5204 module | | - | 24 programmable options | - local PCLINK™ and remote upload/download capability
| - | program system using DLS software and direct PC connection to control panel or via remote PC over telephone line | | - | view status and trouble conditions, and system 128 event buffer | | - | remote access can be controlled by owner to prevent unauthorized access to system | - power supply
| - | 550mA @ 12.5VDC auxiliary power (400mA for UL applications) | | - | positive temperature coefficient (PTC) protected battery, AUX, and Bell output | | - | electronic protection of KEYBUS | | - | supervision of AC power loss, low battery, auxiliary power failure | | - | internal clock locked to AC power frequency | - EEPROM memory
| - | will not lose programming or system status on complete AC and battery failure | - digital communicator
| - | supports all major formats including SIA & Contact ID | | - | supports LINKS1000™ cellular communications | | - | supports LINKS2150™ and LINKS2450™ long range radio communications | | - | 3 phone numbers (3rd backs up primary) | | - | 2 account numbers | | - | DTMF or pulse dialing | | - | DPDT line seizure | | - | anti-jam feature | | - | split reporting of selected events to each telephone number | | - | event initiated personal paging | - battery required : 12V, 4 Ah, rechargeable sealed lead acid
- transformer required : 16.5VAC, 40VA
| | . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . | |  System Operation 2 system partitions… 2 account numbers | - | each partition acts as a separate alarm system with any number of zones, user codes, keypads and individually programmable features | - 38 - 4 or 6 digit access codes
| - | 32 user codes, 1 system master code, 2 partition master codes, 2 duress codes, and 1 maintenance code | - automatic arming by partition
| - | each partition may be programmed to auto-arm at its own time each day | - keypad lockout
| - | panel can be programmed to lockout keypad if a series of incorrect access code entries are made | - 'quick arm' and 'quick exit'
| - | allows users to arm and exit easily | - 'stay/away' zones and 'stay' arming
| - | security of perimeter arming while premise is occupied | - door chime
| - | programmable by zone | | - | monitor a door by having keypad beep when the door is opened and again when door is closed | - 128 event buffer
| - | all events automatically stored with time and date stamp to buffer | | - | events can be printed on-site using the PC5400 serial printer interface module, viewed through an LCD Keypad, or viewed and printed via PC using DLS software |  Full Supervision The system continuously monitors the following trouble conditions : - AC power failure
- trouble by zone
- fire trouble
- telephone line trouble
- low battery
- bell output trouble
- loss of internal clock
- tamper by zone
- fail to communicate
- aux power supply fault
- module fault (supervisory or tamper)
- camera troubles (on PC5015 with Downlook)
 False Alarm Prevention Features - audible exit delay
- audible exit fault
- quick exit
- urgency on entry delay
- swinger shutdown
- cross zone alarm
- recent closing transmission
- burglary verified timer *
- double hit timer *
- communication delay
- rotating keypress buffer
- arm/disarm bell squawk
* on PC5015 v2.2x and higher
| |
|
|
|
|