Sunlight Immune Detector:
A New Standard For Outdoor Detection
Outdoor Detection with the LX-402/802, The Smart Way to Expand Your BusinessOpportunities
OPTEX's outdoor detection offers many advantages for your business. The LX-402/802 isnot only simple to install, but provides greater reliability against false alarms causedby sunlight.
Conventional outdoor passive infrared detectors often produce false alarms caused bysunlight. But, OPTEX's LX-402/802 employs Double Conductive Shielding which resists morethan 50,000 lux of sunlight (e.g. during sunrises and sunsets). This provides highlystable performances, while allowing the units to be used in many different applications.
OptexSpecifications Click Here
| Model | LX-402 | LX-802 |
| Detection Method | Passive Infrared |
| Coverage | 40ft x 50ft (12m x 15m) 120° wide | 80ft x 6ft (24m x 2m) long range |
| Detection Zones | Normal Area: 40 zones | Multi-Level Area: 12 zones |
| Pet alley area: 18 zones | Pet alley area: 4 zones |
| Mounting | Normal Area: 8.3ft (2.5m) max. |
Pet alley area: 4 ~ 5ft (1.2 ~ 1.5m) |
| Detectable Speed | 1 ~ 3.3ft/sec. (0.3 ~ 1.0m/sec) |
| Sensitivity Adjustment | Selectable 3 position (H,M,L) |
| LED Indicator | LED lights on during detection |
| Alarm Period | 2.0 ± 1sec. (Delay timer) |
| Alarm Output | NC. NO 28V DC 0.2A Max |
| Tamper Switch | Opens when cover removed. |
| Pulse Count | 2 position: 2 (20 ± 5 sec.) |
TEST mode: 1 pulse |
| Photocel Adjustment | Day to night mode (Approx. 10 to 100,000 lux) |
| Warm-up Period | Approx. 60 sec. |
| Power Input | 12VDC ± 10% |
| Current Draw | 25mA max. |
| Installation Place | Indoor or outdoor on the wall |
| Operating Temperature | -4°F ~ +122°F (-20°C ~ +50°C) |
| Environment Humidity | 95% max |
| Weight | 5.3oz (150g) |